<_x0034_00929120>
400929120 05A 16700 CHEVRON USA INC
6001 BOLLINGER CANYON RD
SAN RAMON CA 94583 Julie Justus 970 257-6042 970 245-6489 Julie Justus Regulatory Specialist 2015-11-02T14:20:21.733-07:00 DRAFT jjustus 2015-11-02T14:20:21.733-07:00 jjustus jjustus@chevron.com 0.00000 jjustus@chevron.com jjustus jjustus 2015-11-02T15:15:21.86-07:00 400929120 05 103 05852 00 RIO BLANCO WILSON CREEK UNIT 55 NENW 3 2N 94W 6 WILSON CREEK 93352 400929120 Filing Form 5A to update well status and correct previously submitted (2008) Form 5A information. Production equipment (ESP) has been removed and well is isolated from atmosphere by shut in tubing valve and master gate on the tree assembly to completely shut off all outflow. 400929120 400929120 FORM 5A SUBMITTED 400929120.pdf 400929120 400929159 WELLBORE DIAGRAM WCU55_0510305852_WBD_01152015.pdf 101906 400929120 1797209 05A Completed Interval Report 2008 400929120 MR-SN N 6002 6012 20 N 9 1. POOH with 2-7/8" production tubing, RIH with casing scraper to 5905' 2. Lay down scraper 3. RIH with CICR, set retainer @ 5913' 4. Load well with packer fluid, tested tubing to 1000 psi 5. Performed MIT test to 500 psi for 30 min. Good Test 16 Well was TA per above procedure on 08/14/2008 2008-08-14T00:00:00-06:00 TA Thread was being aborted.