FIFTH CREEK ENERGY OPERATING COMPANY LLC           Critter Creek 281-1930H           Well API # 05-123-46220           Status: XX        Status Date: 01/02/2018           Location ID #:453836       Lot 1 19 11N 63W WELD

COGIS - Conditions of Approval
COA Search Results - 2 record(s) returned.
Source
Document
Conditions of Approval
Form: (02 )
401439803
12/20/2017
1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU (spud notice) for the first well activity with a rig on the pad and provide 48 hour spud notice via Form 42 for all subsequent wells drilled on the pad. 2) Provide cement coverage to a minimum of 200' above Niobrara. Verify coverage with cement bond log. 3) Oil-based drilling fluid is to be used only after setting surface casing.
Form: (02 )
401439803
12/20/2017
Bradenhead tests shall be performed and reported according to the following schedule and Form 17 submitted within 10 days of each test.: 1) All: Within 60 days of rig release, prior to stimulation. 2) Delayed completion: 6 months after rig release, prior to stimulation. 3) All: Within 30 days of first production, as reported on Form 5A.


COGIS - Best Management Practices
BMPSearch Results - 2 record(s) returned.
Source
Document
BMP TypeBMP
Form: (02 )
401439803
01/02/2018
Drilling/Completion Operations
Fifth Creek Energy will mitigate any offset wells that are determined to be of concern within 1500’ of any well prior to fracturing operations per the company wide wellbore protection plan. Offset wells of concern within 1500’ of a proposed fracturing operation will be shut in, the pressure will be monitored, and a 5000lb psi well head will be installed.
Form: (02 )
401439803
01/02/2018
Drilling/Completion Operations
The Critter Creek 561-1930 H well will be logged with open-hole Resistivity Log and Gamma Ray Log from the kick-off point into the surface casing. All wells on the pad will have a cement bond log with gamma-ray run on production casing (or on intermediate casing if production liner is run) into the surface casing. The horizontal portion of every well will be logged with a measured-while-drilling gamma-ray log. The Form 5, Completion Report, for each well on the pad will list all logs run and have those logs attached. The Form 5 for a well without open hole logs shall clearly state “No open-hole logs were run” and shall clearly identify (by API#, well name and number) the well in which open-hole logs were run.