EXTRACTION OIL & GAS INC           CDOT-3 D2           Well API # 05-123-24988           Status: PA        Status Date: 06/25/2018           Location ID #:332837       NENE 20 5N 65W WELD

COGIS - Conditions of Approval
COA Search Results - 2 record(s) returned.
Source
Document
Conditions of Approval
Form: (06 )
401351013
07/31/2017
1) Prior to starting plugging operations a Bradenhead test shall be performed. If the beginning pressure is greater than 25 psi, or if pressure remains at the conclusion of the test, or if any liquids were present contact COGCC Engineering for sampling requirements. The Form 17 shall be submitted within 10 days of the test.
Form: (06 )
401351013
07/31/2017
1) Provide 48 hour notice of plugging MIRU via electronic Form 42. 2) For the 630’ plug: pump plug and displace. If surface casing plug is not circulated to surface then tag plug – must be at 429’ or shallower and provide 10 sx plug at the surface. Leave at least 100’ of cement in the casing for each plug. 3) Properly abandon flowlines as per Rule 1103. File electronic Form 42 once abandonment complete.